Keyence FT-50AW Digital Infrared Temperature Amplifier w/ FT-H30 Sensor Head
Here are similar parts that are in stock and ready to ship.
About this item
This listing is for a Keyence FT-50AW DIN Rail Digital Infrared Temperature Amplifier with FT-H30 Digital Infrared Temperature Sensor Heads with mounting brackets.
Model
FT-50AW
Type
DIN-rail mounting type
Power voltage
12 to 24 VDC, Ripple (P-P)10% max.
Power
consumption
Normal
1400 mW (For 12 V), 1600 mW (For 24 V)
Eco mode
1150 mW (For 12 V), 1350 mW (For 24 V)
Display method
4 + 1/two-digit 7-segment LED, dual-display (red/green) display (character height in the upper display (red): 8 mm 0.31",
character height in the lower display (green): 5.7 mm 0.22"), Display updating cycle: 10/s
Operation indicator
Red LED x 3 (control output1/control output2/timing input indicator)
Display resolution
0.1°C or 1°C 0.2°F or 1.8°F (when using FT-H10/H20/H30), 1°C 1.8°F (when using FT-H50/H40K/H50K)
Hysteresis
Variable
Response speed
HSP, 30, 100, 200, 500, 1000, or 5000 ms can be selected (In HSP: 15 ms max.)
Bank selection
Pink and Purple wires can be configured for Bank Inputs #1,2 respectively for up to 4 total banks.
External input
Timing input
Input time: 2 ms min.
Bank input
Input time: 20 ms min.
Control output
NPN open collector x 2 channels (N.O./N.C. selectable), 100 mA max. (40 VDC max.), residual voltage: 1 V max.
Analog output
4 to 20 mA, maximum load resistance: 260 ? The upper- and lower-limit values of the analog output range can be set optionally.
Emissivity (valid in temperature mode) and limit settings x 2 can be set for each bank.
Environmental resistance
Ambient temperature
-10 to +50 °C 14 to 122 °F (No freezing)*1
Relative humidity
35 to 85 % RH (No condensation)
Vibration resistance
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis
Material
Main unit, Cover: Polycarbonate, Keycaps: Polyester elastomer, Cable: Vinyl chloride
Mounting bracket: SUS304
Accessory
DIN anchoring fixture, power cable, unit cover sticker
Model
FT-H30
Type
Mid to low temperature, Long-range
Rated temperature range
0 to 500°C 32 to 932°F*1
Displayable temperature range
-50 to +520°C -58 to +968°F
Detecting distance
Unlimited*2
Measuring distance /
View diameter (example)
200/ø15 mm 7.87"/ø0.59"
400/ø18 mm 15.75"/ø0.71"
600/ø33 mm 23.62"/ø1.30"
Sight
2-point visible laser beam*3
Detecting element
Thermopile
Detecting wavelength
8 to 14 µm
Repeatability
±0.5°C 0.9°F
Emissivity (e) correction
0.10 to 1.99 (0.01 step)
Environmental resistance
Ambient temperature
-10 to +55 °C 14 to 131 °F (No freezing)
Relative humidity
35 to 85 % RH (No condensation)
Vibration resistance
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis
Shock resistance
500 m/s2, 10 times in each direction of each of X, Y and Z axis, 60 times in total
Material
Case: Reinforced glass plastic, Infrared collector lens: Germanium, Laser transmitter: Polyarylate
Cable: Vinyl chloride, Mounting bracket: SUS304, Mounting screw: Stainless steel
Accessory
Mounting bracket
Shipping & returns
Orders leave our Rochester, NY warehouse within one business day, and express shipping is available at checkout. Returns are accepted within 30 days. Shipping policy · Return policy
Similar parts in stock